BTU Meters
The System-10 BTU Meter is a highly accurate microprocessor-based instrument designed to provide full energy, flow and temperature data both at the front panel LCD and over an optional serial network interface. The System-10 is also available with optional analog output signals for energy, flow and temperature. The System-10 is the ideal choice for networking to control systems with the availability of LONWORKS®, MODBUS®, Johnson Controls-N2, Siemens-P1 and BACnet® interface cards. |
|
|
|
BTU Meters - System-40
The System-40 provides highly accurate thermal energy measurement in chilled water, hot water or condenser water systems. It is provided as a complete meter and includes a matched pair of platinum RTD temperature sensors and an integral inline ultrasonic flow sensor. It is available for use in ½” through 2” piping systems with flow rates ranging from 0.03 to 70 GPM.
The native BACnet® MS/TP version of the meter communicates energy, flow and temperature data directly to the network. This version also provides 3 auxiliary pulse inputs for totalizing the pulse outputs from external devices such as water, natural gas or electric meters. Pulse totals are accumulated in internal registers and then transmitted to the network. These totals are also available on the built-in display.
|
|
|
|
Class 1000 Single-Phase kWh Submeter
- Direct-read 8-digit LCD display without multiplier displays cumulative kWh and "real-time kW load.
Revenue Grade Metering Accuracy.
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 2,000 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
- Parallel up to three (3) sets of current sensors for cumulative reading.
- Current sensor installation diagnostics.
|
|
|
|
Class 4000 Multi-Family Single-Phase kWh Submeter
- Easy-to-read 6-digit electromechanical display.
- Revenue Grade Metering Accuracy.
- Certified to ANSI C12.1 and C12.16 national accuracy standards.
- Certified to California measuring standards Bureau of Weights & Measures.
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 2,000 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
- Meter can be used in the following configurations:
1-Phase, 2 Wire - 2-Phase, 3 Wire
- Sealing option for California applications available.
- UL Listed.
- Measurement Canada approved for revenue metering.
- New York City approved, Con Edison approved for RSP program.
|
|
|
|
Class 2000 Three-Phase kWh/kW (Demand) Submeter
- Direct-read 8-digit LCD display without multiplier displays cumulative kWh and "real-time kW load.
- Demand option displays kW/Demand and kW peak date and time (15 minute interval standard, 30 minute interval available.)
- Revenue Grade Metering Accuracy.
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 2,000 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
- Current sensor installation diagnostics indicator.
- Parallel up to three (3) sets of current sensors for cumulative reading.
|
|
|
|
Class 3000 Advanced Submeter with Communications
- Easy to read cycling 4-line by 20 character backlit LCD display:
- kWh - kWh/Demand (with peak date and time) - Power factor per Phase - Real-time load in kW - Amps per Phase - Volts per Phase
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 500 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
- Installation diagnostics and verification system.
- Revenue Grade Accuracy
- RS-485 communication capability supports the following connection configurations (or combinations not to exceed 52 devices per channel):
- Up to 52 Class 3000 meters and/or IDR-8 interval data recorders.
- Up to 26 IDR-16 interval data recorders (IDR-16 counts as two devices)
- Cabling can either be daisy-chain or star configuration, 4-conductor, 24-26 AWG, up to 4,000 cable feet total per channel
|
|
|
|
Class 5000 Advanced Submeter with Communications - Government Meter
- Direct-read 8-digit LCD display of cumulative kWh.
E-Mon Energy software supports load profiling (5 or 15 minute) of kWh & kVARh.
E-Mon Energy software supports real-time reading of:
Amps per Phase - Volts per Phase-to-Neutral - Volts per Phase-to-Phase - kW, kVA and kVAR per Phas - Total kW, kVA and kVA - Frequency - Power Factor Percent & Angle per Phase
- Open protocol for easy integration to various building automation and energy management systems, including optional Modbus RTU & TCP/IP, BACnet IP & MS/TP and LonWorks Twisted Pair.
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 500 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
- Current sensor installation diagnostics indicator on display.
- Revenue Grade Accuracy.
|
|
|
|
Green Class Meter with CO2 & Carbon Footprint Data
- Direct-read 8-digit LCD display without multiplier displays cumulative kWh and "real-time kW load.
- User entered cost per kWh provides to-date energy cost and projected hourly cost based on metered load.
- Displays total carbon (CO2) emissions in pounds (lbs.) and indicates hourly emissions based on metered load.
- Revenue Grade Metering Accuracy.
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 2,000 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp only.)
- Current sensor installation diagnostics indicator.
- Parallel up to three (3) sets of current sensors for cumulative reading.
|
|
|
|
Green Class Meter with Net Metering Capabilities
- Direct-read 8-digit LCD display of delivered kWh, received kWh, net kWh and real-time load in kW.
- Meter provides load profile data of delivered kWh, delivered kVARh and received kWh along with real-time readings of Power Factor, kW, kVa, kVAR, Amps per phase, Volts per phase and Frequency; available via E-Mon Energy software.
- Displays total carbon (CO2) emissions in pounds (lbs.) based on DOE national average and indicates hourly emissions based on metered load.
- Communication options include telephone modem, RS-232/RS-485 and Ethernet.
- MV-90 compatible.
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 500 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp only.)
- Current sensor installation diagnostics indicator.
- Optional fixed-value pulse output of delivered kWh.
- Non-volatile memory.
|
|